ScholarGate
Assistent
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Åpne i MethodMindSnartBruk, sammenlign, få veiledning
Verktøy og ressurser
Last ned lysbilder
Lær og utforsk
VideoSnart

Les hele metoden

Kun for medlemmer

Logg inn med en gratis konto for å lese denne delen.

Logg inn

Metodekart

Nabolaget av beslektede metoder — velg en node for å utforske.

Kilder

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Slik siterer du denne siden

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/no/sport-leisure-studies/accelerometer-cut-point-calibration

Hvilken metode?

Sett denne metoden ved siden av sin nærmeste slektning og les dem side om side — biblioteket legger bøkene på bordet; valget er ditt.

Sammenlign side om side

Referert av

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Hentet 2026-06-24 fra https://scholargate.app/no/sport-leisure-studies/accelerometer-cut-point-calibration · Datasett: https://doi.org/10.5281/zenodo.20539026