ScholarGate
Asistente
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Abrir en MethodMindPróximamenteAplicar, comparar, obtener orientación
Herramientas y recursos
Descargar diapositivas
Aprender y explorar
VídeoPróximamente

Leer el método completo

Solo para miembros

Inicia sesión con una cuenta gratuita para leer esta sección.

Iniciar sesión

Mapa de métodos

El vecindario de métodos relacionados: selecciona un nodo para explorarlo.

Fuentes

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Cómo citar esta página

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/es/sport-leisure-studies/accelerometer-cut-point-calibration

¿Qué método?

Coloca este método junto a sus parientes más cercanos y léelos lado a lado: la biblioteca pone los libros sobre la mesa; la elección es tuya.

Comparar lado a lado

Citado por

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Recuperado el 2026-06-24 de https://scholargate.app/es/sport-leisure-studies/accelerometer-cut-point-calibration · Conjunto de datos: https://doi.org/10.5281/zenodo.20539026