Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Otvorite u MethodMindUskoroPrimijenite, usporedite, dobijte smjernice
Alati i resursi
Preuzmi prezentaciju
Učenje i istraživanje
VideoUskoro

Pročitajte cijelu metodu

Samo za članove

Prijavite se besplatnim računom kako biste pročitali ovaj odjeljak.

Prijavite se

Karta metoda

Okruženje srodnih metoda — odaberite čvor za istraživanje.

Izvori

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Kako citirati ovu stranicu

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/hr/sport-leisure-studies/accelerometer-cut-point-calibration

Koja metoda?

Postavite ovu metodu uz njoj najsrodnije i pročitajte ih jednu uz drugu — knjižnica vam knjige stavlja na stol; izbor je na vama.

Usporedi jedno uz drugo

Citirana u

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Preuzeto 2026-06-24 s https://scholargate.app/hr/sport-leisure-studies/accelerometer-cut-point-calibration · Skup podataka: https://doi.org/10.5281/zenodo.20539026