ScholarGate
Assistant
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Ouvrir dans MethodMindBientôtAppliquer, comparer, obtenir des conseils
Outils et ressources
Télécharger les diapositives
Apprendre et explorer
VidéoBientôt

Lire la méthode complète

Réservé aux membres

Connectez-vous avec un compte gratuit pour lire cette section.

Se connecter

Carte des méthodes

Le voisinage des méthodes apparentées — sélectionnez un nœud pour explorer.

Sources

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Comment citer cette page

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/fr/sport-leisure-studies/accelerometer-cut-point-calibration

Quelle méthode ?

Placez cette méthode aux côtés de ses plus proches parentes et lisez-les côte à côte — la bibliothèque pose les ouvrages sur la table ; le choix vous revient.

Comparer côte à côte

Référencée par

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Consulté le 2026-06-24 sur https://scholargate.app/fr/sport-leisure-studies/accelerometer-cut-point-calibration · Jeu de données : https://doi.org/10.5281/zenodo.20539026