ScholarGate
Асистент
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Отворете в MethodMindСкороПриложете, сравнете, получете насоки
Инструменти и ресурси
Изтегляне на слайдове
Учене и проучване
ВидеоСкоро

Прочетете целия метод

Само за членове

Влезте с безплатен профил, за да прочетете този раздел.

Вход

Карта на методите

Обкръжението на сродните методи — изберете възел, за да го разгледате.

Източници

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Как да цитирате тази страница

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/bg/sport-leisure-studies/accelerometer-cut-point-calibration

Кой метод?

Поставете този метод до най-близките му сродни методи и ги четете едно до друго — библиотеката полага книгите на масата; изборът е ваш.

Сравняване едно до друго

Цитиран в

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Извлечено на 2026-06-24 от https://scholargate.app/bg/sport-leisure-studies/accelerometer-cut-point-calibration · Набор от данни: https://doi.org/10.5281/zenodo.20539026