ScholarGate
Assistent
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Öppna i MethodMindSnartTillämpa, jämför, få vägledning
Verktyg och resurser
Ladda ner bildspel
Lär dig och utforska
VideoSnart

Läs hela metoden

Endast för medlemmar

Logga in med ett kostnadsfritt konto för att läsa avsnittet.

Logga in

Metodkarta

Närområdet av besläktade metoder — välj en nod för att utforska.

Källor

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Så citerar du den här sidan

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/sv/sport-leisure-studies/accelerometer-cut-point-calibration

Vilken metod?

Placera den här metoden bredvid sina närmaste släktingar och läs dem sida vid sida — biblioteket lägger fram böckerna på bordet; valet är ditt.

Jämför sida vid sida

Refereras av

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Hämtad 2026-06-24 från https://scholargate.app/sv/sport-leisure-studies/accelerometer-cut-point-calibration · Datamängd: https://doi.org/10.5281/zenodo.20539026