ScholarGate
Asistents
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Atvērt MethodMindDrīzumāLietojiet, salīdziniet, saņemiet norādījumus
Rīki un resursi
Lejupielādēt slaidus
Mācieties un izpētiet
VideoDrīzumā

Lasīt pilno metodes aprakstu

Tikai dalībniekiem

Piesakieties ar bezmaksas kontu, lai lasītu šo sadaļu.

Pieteikties

Metožu karte

Saistīto metožu apkaime — atlasiet mezglu, lai izpētītu.

Avoti

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Kā citēt šo lapu

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/lv/sport-leisure-studies/accelerometer-cut-point-calibration

Kura metode?

Novietojiet šo metodi blakus tās tuvākajām radniecīgajām metodēm un lasiet tās līdzās — bibliotēka noliek grāmatas uz galda; izvēle ir jūsu.

Salīdzināt blakus

Uz to atsaucas

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Izgūts 2026-06-24 no https://scholargate.app/lv/sport-leisure-studies/accelerometer-cut-point-calibration · Datu kopa: https://doi.org/10.5281/zenodo.20539026