ScholarGate
Asisten
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Buka di MethodMindSegeraTerapkan, bandingkan, dapatkan panduan
Alat & sumber daya
Unduh salindia
Belajar & jelajahi
VideoSegera

Baca metode selengkapnya

Khusus anggota

Masuk dengan akun gratis untuk membaca bagian ini.

Masuk

Peta metode

Lingkup metode terkait — pilih sebuah simpul untuk menjelajah.

Sumber

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Cara menyitasi halaman ini

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/id/sport-leisure-studies/accelerometer-cut-point-calibration

Metode yang mana?

Letakkan metode ini berdampingan dengan kerabat terdekatnya dan baca secara bersisian — pustaka menata bukunya di atas meja; pilihan ada di tangan Anda.

Bandingkan berdampingan

Dirujuk oleh

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Diakses 2026-06-24 dari https://scholargate.app/id/sport-leisure-studies/accelerometer-cut-point-calibration · Set data: https://doi.org/10.5281/zenodo.20539026