ScholarGate
Assistent
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Åbn i MethodMindSnartAnvend, sammenlign, få vejledning
Værktøjer og ressourcer
Hent slides
Lær og udforsk
VideoSnart

Læs hele metoden

Kun for medlemmer

Log ind med en gratis konto for at læse dette afsnit.

Log ind

Metodekort

Nabolaget af beslægtede metoder — vælg en knude for at udforske.

Kilder

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Sådan citerer du denne side

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/da/sport-leisure-studies/accelerometer-cut-point-calibration

Hvilken metode?

Stil denne metode ved siden af dens nærmeste slægtninge, og læs dem side om side — biblioteket lægger bøgerne på bordet; valget er dit.

Sammenlign side om side

Refereret af

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Hentet 2026-06-24 fra https://scholargate.app/da/sport-leisure-studies/accelerometer-cut-point-calibration · Datasæt: https://doi.org/10.5281/zenodo.20539026