ScholarGate
助手

方法对比

并排查看您选择的方法;存在差异的行会高亮显示。

溶胀与降解×骨形态发生蛋白(BMP)释放测定×动态力学分析×静电纺丝×
领域生物材料生物材料生物材料生物材料
方法族Process / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
起源年份1960196519601934
提出者Wichterle and LimMarshall UristFerry and SchwarzlAnton Formhals
类型Kinetic assayKinetic release assayRheological characterizationFiber fabrication process
开创性文献Wichterle, O., & Lim, D. (1960). Hydrophilic gels for biological use. Nature, 185(4706), 117-118. DOI ↗Urist, M. R. (1965). Bone: formation by autoinduction. Science, 150(3698), 893-899. DOI ↗Menard, K. P. (2008). Dynamic mechanical analysis: a practical introduction (2nd ed.). CRC Press. link ↗Formhals, A. (1934). Process and apparatus for preparing artificial threads. U.S. Patent 1,975,504. link ↗
别名hydrogel swelling, polymer degradation, mass loss assayBMP release kinetics, BMP elution profile, growth factor release assayDMA, rheological analysis, viscoelastic testingelectrospun fiber production, electrostatic fiber spinning
相关4433
摘要The swelling and degradation assay measures how biomaterial scaffolds absorb water (swelling) and lose mass over time due to degradation. Developed by Wichterle and Lim in 1960 for hydrogels, the assay is fundamental for characterizing hydrogels, synthetic polymers, and composite scaffolds intended for tissue engineering. The assay provides quantitative data on swelling kinetics (equilibrium water content, swelling ratio), degradation kinetics (mass loss rate, half-life), and mechanisms of degradation (chain scission, enzymatic breakdown).The bone morphogenetic protein (BMP) release assay measures the kinetics and amount of BMP elution from a biomaterial carrier over time. BMP-2, BMP-6, BMP-7, and BMP-9 are potent osteoinductive growth factors discovered by Marshall Urist in 1965 that trigger bone and cartilage formation. When loaded into scaffolds, hydrogels, or implants, BMPs must be released in a controlled manner to maximize biological effect while minimizing systemic exposure. The release assay quantifies how much BMP is present in the surrounding medium at defined timepoints, enabling optimization of carrier materials and release profiles for bone regeneration and fracture healing applications.Dynamic mechanical analysis (DMA) measures the viscoelastic properties of materials—their elastic stiffness and viscous damping—by applying a sinusoidal stress or strain and measuring the phase lag and amplitude of the material's response. Developed from rheology principles in the 1960s and formalized by Ferry, Schwarzl, and others, DMA provides quantitative measures of how polymeric biomaterials respond to time-dependent and frequency-dependent mechanical stimuli. Key outputs include the storage modulus (elastic component), loss modulus (viscous component), and loss tangent (tan δ), which together characterize the material's mechanical behavior across temperature and frequency ranges.Electrospinning is an electrostatic fiber fabrication process that uses a high electric field to draw polymer solutions or melts into nanoscale fibers. Developed by Anton Formhals in the 1930s and refined by researchers including Darrell Reneker in the 1990s, the technique has become foundational to biomaterials engineering, enabling the creation of porous scaffolds for tissue engineering and drug delivery systems.
ScholarGate数据集
  1. v1
  2. 3 来源
  3. PUBLISHED
  1. v1
  2. 3 来源
  3. PUBLISHED
  1. v1
  2. 3 来源
  3. PUBLISHED
  1. v1
  2. 3 来源
  3. PUBLISHED

前往搜索 下载幻灯片

ScholarGate方法对比: Swelling and Degradation · BMP Release · Dynamic Mechanical Analysis · Electrospinning. 于 2026-06-19 检索自 https://scholargate.app/zh/compare