ScholarGate
Asistent

Compară metode

Examinează metodele selectate una lângă alta; rândurile care diferă sunt evidențiate.

XANES×ATR-FTIR×EXAFS×
DomeniuSpectroscopieSpectroscopieSpectroscopie
FamilieProcess / pipelineProcess / pipelineProcess / pipeline
Anul apariției197519611971
Autorul originalPeter LeeJoop FahrenfortEdward Stern
TipSynchrotron techniqueVibrational spectroscopy techniqueSynchrotron technique
Sursa seminalăLee, P. A., & Pendry, J. B. (1975). Theory of extended x-ray absorption fine structure. Physical Review B, 11(8), 2795-2811. DOI ↗Harrick, N. J. (1960). Study of physics of internal reflection from metals. Journal of Physics and Chemistry of Solids, 13(2), 143-155. link ↗Sayers, D. E., Stern, E. A., & Lytle, F. W. (1971). New technique for investigating noncrystalline structures: Fourier analysis of the extended X-ray absorption fine structure. Physical Review Letters, 27(18), 1204-1207. DOI ↗
Denumiri alternativeXANES spectroscopy, near-edge X-ray absorptionATR-IR, attenuated total reflectance, FTIR spectroscopyEXAFS spectroscopy, X-ray absorption spectroscopy
Înrudite333
RezumatX-ray Absorption Near Edge Structure (XANES) is a synchrotron X-ray spectroscopy technique that measures the electronic and geometric structure around a specific atom by analyzing the X-ray absorption spectrum within about 50 eV of an absorption edge. Developed by Lee and Pendry in 1975, XANES is complementary to EXAFS and reveals valence state, local symmetry, and unoccupied orbital structure through near-threshold features and resonances.Attenuated Total Reflectance (ATR) Fourier Transform Infrared (FTIR) spectroscopy is a variant of conventional FTIR that measures infrared absorption through evanescent-wave interrogation of samples in direct contact with a high-refractive-index crystal. Developed by Harrick and Fahrenfort in the 1960s, ATR-FTIR is now the dominant form of FTIR spectroscopy, enabling rapid, non-destructive characterization of organic compounds, polymers, coatings, and biological materials without extensive sample preparation.Extended X-ray Absorption Fine Structure (EXAFS) is a synchrotron-based X-ray spectroscopy technique that measures the local geometric and electronic structure around a specific atom in any material, crystal or amorphous. Discovered by Sayers, Stern, and Lytle in 1971, EXAFS reveals interatomic distances, coordination numbers, and disorder in the atomic environment by analyzing oscillations in the X-ray absorption spectrum above an absorption edge.
ScholarGateSet de date
  1. v1
  2. 2 Surse
  3. PUBLISHED
  1. v1
  2. 3 Surse
  3. PUBLISHED
  1. v1
  2. 2 Surse
  3. PUBLISHED

Mergi la căutare Descarcă prezentarea

ScholarGateCompară metode: XANES · ATR-FTIR · EXAFS. Preluat la 2026-06-19 de pe https://scholargate.app/ro/compare