ScholarGate
Assistent
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

In MethodMind öffnenDemnächstAnwenden, vergleichen, Anleitung erhalten
Werkzeuge und Ressourcen
Folien herunterladen
Lernen und erkunden
VideoDemnächst

Die vollständige Methode lesen

Nur für Mitglieder

Melden Sie sich mit einem kostenlosen Konto an, um diesen Abschnitt zu lesen.

Anmelden

Methodenkarte

Die Nachbarschaft verwandter Methoden — wählen Sie einen Knoten, um sie zu erkunden.

Quellen

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

So zitieren Sie diese Seite

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/de/sport-leisure-studies/accelerometer-cut-point-calibration

Welche Methode?

Stellen Sie diese Methode neben ihre nächsten Verwandten und lesen Sie sie nebeneinander — die Bibliothek legt die Bücher auf den Tisch; die Wahl liegt bei Ihnen.

Nebeneinander vergleichen

Referenziert von

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Abgerufen am 2026-06-24 von https://scholargate.app/de/sport-leisure-studies/accelerometer-cut-point-calibration · Datensatz: https://doi.org/10.5281/zenodo.20539026