ScholarGate
助手

方法对比

并排查看您选择的方法;存在差异的行会高亮显示。

ATR-FTIR×圆二色性×表面等离激元共振×
领域光谱学光谱学光谱学
方法族Process / pipelineProcess / pipelineProcess / pipeline
起源年份196119691971
提出者Joop FahrenfortJean-Claude FasmanErich Kretschmann
类型Vibrational spectroscopy techniqueSpectroscopic methodOptical technique
开创性文献Harrick, N. J. (1960). Study of physics of internal reflection from metals. Journal of Physics and Chemistry of Solids, 13(2), 143-155. link ↗Greenfield, N. J., & Fasman, G. D. (1969). Computed circular dichroism spectra for protein secondary structures. Biochemistry, 8(10), 4108-4116. DOI ↗Kretschmann, E. (1971). Determination of optical constants of metals by excitation of surface plasmons. Zeitschrift für Physik, 241(4), 313-324. link ↗
别名ATR-IR, attenuated total reflectance, FTIR spectroscopyCD spectroscopy, circular dichroism, CD analysisSPR, surface plasmon, SPR biosensing
相关333
摘要Attenuated Total Reflectance (ATR) Fourier Transform Infrared (FTIR) spectroscopy is a variant of conventional FTIR that measures infrared absorption through evanescent-wave interrogation of samples in direct contact with a high-refractive-index crystal. Developed by Harrick and Fahrenfort in the 1960s, ATR-FTIR is now the dominant form of FTIR spectroscopy, enabling rapid, non-destructive characterization of organic compounds, polymers, coatings, and biological materials without extensive sample preparation.Circular Dichroism (CD) spectroscopy measures the differential absorption of left- and right-circularly polarized light by optically active molecules, particularly proteins and nucleic acids. Introduced by Greenfield and Fasman in 1969, CD is a rapid, non-destructive technique for characterizing secondary structure (alpha-helix, beta-sheet), monitoring protein folding transitions, and assessing conformational changes in response to pH, temperature, or ligand binding.Surface Plasmon Resonance (SPR) is a real-time, label-free technique for detecting and monitoring biomolecular interactions at a sensor surface by measuring changes in the refractive index caused by ligand binding. Developed by Kretschmann in 1971 and applied to biosensing by Liedberg, Nylander, and Lundström in 1983, SPR is now a gold standard for measuring binding kinetics (association and dissociation rates) and equilibrium binding constants in protein interactions, antibody-antigen recognition, and drug discovery.
ScholarGate数据集
  1. v1
  2. 3 来源
  3. PUBLISHED
  1. v1
  2. 2 来源
  3. PUBLISHED
  1. v1
  2. 3 来源
  3. PUBLISHED

前往搜索 下载幻灯片

ScholarGate方法对比: ATR-FTIR · Circular Dichroism · Surface Plasmon Resonance. 于 2026-06-19 检索自 https://scholargate.app/zh/compare