ScholarGate
Asistenti

Krahasoni metodat

Shqyrtoni metodat e zgjedhura krah për krah; rreshtat që ndryshojnë janë të theksuar.

Vlerësim Pas-Përdorimit×Analiza e Dizajnit Akustik×Simulimi i Dritës së Ditës×Vlerësimi i Komfortit Termik×
FushaArkitekturëArkitekturëArkitekturëArkitekturë
FamiljaProcess / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
Viti i origjinës1988192220061972
KrijuesiWolfgang PreiserWallace Clement SabineChristoph Reinhart, John MardaljevicPovl Ole Fanger
Llojiempirical building evaluation methodroom acoustic prediction and assessment methodcomputational daylighting assessment methodpsychrometric comfort assessment method
Burimi themeluesPreiser, W. F., Rabinowitz, H. Z., White, E. T. (1988). Post-Occupancy Evaluation. Van Nostrand Reinhold, New York. link ↗Sabine, W. C. (1922). Collected Papers on Acoustics. Harvard University Press, Cambridge, MA. link ↗Reinhart, C. F., Mardaljevic, J., Rogers, Z. (2010). Dynamic Daylight Performance Metrics for Sustainable Building Design. Leukos, 3(1), 7-31. DOI ↗Fanger, P. O. (1972). Thermal Comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press, Copenhagen. link ↗
Emërtime të tjeraPOE, building performance evaluation, occupant satisfaction assessmentsound analysis, room acoustic design, noise predictiondaylighting analysis, illuminance simulation, daylight availability assessmentthermal comfort evaluation, adaptive comfort model, PMV-PPD analysis
Të lidhura3333
PërmbledhjaPost-Occupancy Evaluation (POE) is a systematic method for assessing how well a completed building meets the needs and expectations of its occupants, comparing planned performance to actual performance. Formalized by Wolfgang Preiser in the 1980s, POE has become essential for learning what design strategies work, identifying problems for remediation, and improving future projects.Acoustic Design Analysis is a method for evaluating the acoustical properties of buildings to predict sound levels, reverberation time, and speech intelligibility. Founded by Wallace Clement Sabine in the early 1900s, the field encompasses room acoustic design (controlling reverberation), sound transmission loss (preventing noise transfer between spaces), and environmental noise prediction.Daylight Simulation is a computational method for predicting the availability and distribution of daylight in interior spaces and assessing visual comfort under varying sky conditions. Developed by researchers like Christoph Reinhart and John Mardaljevic in the 2000s, it has become central to designing healthy, energy-efficient buildings that maximize natural light while controlling glare.Thermal Comfort Assessment is a method for evaluating indoor environmental conditions to predict whether occupants will feel thermally comfortable. Pioneered by Povl Ole Fanger in the 1970s, it combines measurements of air temperature, humidity, air speed, and thermal properties of clothing and activity to determine comfort zones and identify remedial actions.
ScholarGateSeti i të dhënave
  1. v1
  2. 3 Burimet
  3. PUBLISHED
  1. v1
  2. 3 Burimet
  3. PUBLISHED
  1. v1
  2. 3 Burimet
  3. PUBLISHED
  1. v1
  2. 3 Burimet
  3. PUBLISHED

Shko te kërkimi Shkarko diapozitivat

ScholarGateKrahasoni metodat: Post-Occupancy Evaluation · Acoustic Design Analysis · Daylight Simulation · Thermal Comfort Assessment. Marrë më 2026-06-20 nga https://scholargate.app/sq/compare