ScholarGate
Asistent

Porovnať metódy

Prezrite si vybrané metódy vedľa seba; riadky, ktoré sa líšia, sú zvýraznené.

Variabilita srdcovej frekvencie×Detekcia QRS podľa Pan-Tompkins×Fotopletyzmografia×Model Windkessel×
OdborBiomechanikaBiomechanikaBiomechanikaBiomechanika
RodinaProcess / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
Rok vzniku1996198519371969
TvorcaTask Force of European Society of CardiologyJiapu PanHertzmanNikolaos Westerhof
TypTime-series and frequency-domain analysis pipelineDigital signal processing pipelineOptical signal acquisition and analysis pipelinePhysiological lumped-parameter modeling
Pôvodný zdrojTask Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. (1996). Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation, 93(5), 1043-1065. DOI ↗Pan, J., & Tompkins, W. J. (1985). A real-time QRS detection algorithm. IEEE Transactions on Biomedical Engineering, BME-32(3), 230-236. DOI ↗Allen, J. (2007). Photoplethysmography and its application in clinical physiology. Physiology & Behavior, 107(4), 540-548. link ↗Westerhof, N., Bosman, F., De Vries, N. C., & Noordergraaf, A. (1969). Analog studies of the human systemic arterial tree. Journal of Biomechanics, 2(2), 121-143. DOI ↗
Ďalšie názvyHRV, RR interval analysis, Cardiac variabilityQRS detection, R-peak detection, Heartbeat detectionPPG, Pulse oximetry, Reflectance photometryElastic chamber model, Arterial compliance model, Lumped parameter model
Príbuzné3333
ZhrnutieHeart rate variability (HRV) analysis quantifies the variation in time intervals between consecutive heartbeats as a window into autonomic nervous system function and cardiovascular health. Formalized by the European Society of Cardiology Task Force in 1996, HRV metrics are now standard in cardiology, physiology, and sports science for assessing stress, recovery, and disease risk.The Pan-Tompkins algorithm is a real-time QRS detection method for electrocardiograms (ECGs) that identifies the R-peaks (ventricular depolarization) and QRS complexes from continuous cardiac waveforms. Published by Jiapu Pan and Willis Tompkins in 1985, it remains a standard reference for ECG processing and is widely implemented in clinical monitoring systems.Photoplethysmography (PPG) measures blood volume changes in tissue using light absorption, providing a non-invasive optical window into cardiovascular dynamics. Originally developed by Hertzman in 1937, PPG is now ubiquitous in pulse oximetry, smartwatches, and research applications for monitoring heart rate, blood oxygenation, and vascular function.The Windkessel model is a lumped-parameter representation of the arterial system that captures the pulsatile dynamics of blood flow and pressure using simple mechanical analogs (resistors and capacitors). Named after the German word for air chamber, it was formalized by Westerhof and colleagues in the late 1960s and remains fundamental to understanding arterial hemodynamics and blood pressure regulation.
ScholarGateDátová sada
  1. v1
  2. 2 Zdroje
  3. PUBLISHED
  1. v1
  2. 2 Zdroje
  3. PUBLISHED
  1. v1
  2. 2 Zdroje
  3. PUBLISHED
  1. v1
  2. 2 Zdroje
  3. PUBLISHED

Prejsť na hľadanie Stiahnuť snímky

ScholarGatePorovnať metódy: Heart Rate Variability · Pan-Tompkins QRS Detection · Photoplethysmography · Windkessel Model. Získané 2026-06-20 z https://scholargate.app/sk/compare