ScholarGate
Asistents

Salīdzināt metodes

Apskatiet izvēlētās metodes blakus; rindas, kas atšķiras, ir izceltas.

Sirds ritma variabilitāte×Pan-Tompkins QRS detekcija×Fotopletizmogrāfija×
NozareBiomehānikaBiomehānikaBiomehānika
SaimeProcess / pipelineProcess / pipelineProcess / pipeline
Izcelsmes gads199619851937
AutorsTask Force of European Society of CardiologyJiapu PanHertzman
TipsTime-series and frequency-domain analysis pipelineDigital signal processing pipelineOptical signal acquisition and analysis pipeline
PirmavotsTask Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. (1996). Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation, 93(5), 1043-1065. DOI ↗Pan, J., & Tompkins, W. J. (1985). A real-time QRS detection algorithm. IEEE Transactions on Biomedical Engineering, BME-32(3), 230-236. DOI ↗Allen, J. (2007). Photoplethysmography and its application in clinical physiology. Physiology & Behavior, 107(4), 540-548. link ↗
Citi nosaukumiHRV, RR interval analysis, Cardiac variabilityQRS detection, R-peak detection, Heartbeat detectionPPG, Pulse oximetry, Reflectance photometry
Saistītās333
KopsavilkumsHeart rate variability (HRV) analysis quantifies the variation in time intervals between consecutive heartbeats as a window into autonomic nervous system function and cardiovascular health. Formalized by the European Society of Cardiology Task Force in 1996, HRV metrics are now standard in cardiology, physiology, and sports science for assessing stress, recovery, and disease risk.The Pan-Tompkins algorithm is a real-time QRS detection method for electrocardiograms (ECGs) that identifies the R-peaks (ventricular depolarization) and QRS complexes from continuous cardiac waveforms. Published by Jiapu Pan and Willis Tompkins in 1985, it remains a standard reference for ECG processing and is widely implemented in clinical monitoring systems.Photoplethysmography (PPG) measures blood volume changes in tissue using light absorption, providing a non-invasive optical window into cardiovascular dynamics. Originally developed by Hertzman in 1937, PPG is now ubiquitous in pulse oximetry, smartwatches, and research applications for monitoring heart rate, blood oxygenation, and vascular function.
ScholarGateDatu kopa
  1. v1
  2. 2 Avoti
  3. PUBLISHED
  1. v1
  2. 2 Avoti
  3. PUBLISHED
  1. v1
  2. 2 Avoti
  3. PUBLISHED

Doties uz meklēšanu Lejupielādēt slaidus

ScholarGateSalīdzināt metodes: Heart Rate Variability · Pan-Tompkins QRS Detection · Photoplethysmography. Izgūts 2026-06-20 no https://scholargate.app/lv/compare