ScholarGate
Asisten

Bandingkan metode

Tinjau metode pilihan Anda berdampingan; baris yang berbeda akan disorot.

Interaksi Konfigurasi×EXAFS×XANES×
BidangSpektroskopiSpektroskopiSpektroskopi
KeluargaProcess / pipelineProcess / pipelineProcess / pipeline
Tahun asal196019711975
PencetusClemens RoothaanEdward SternPeter Lee
TipeComputational methodSynchrotron techniqueSynchrotron technique
Sumber perintisRoothaan, C. C. J. (1960). New developments in molecular orbital theory. Reviews of Modern Physics, 32(2), 179-185. link ↗Sayers, D. E., Stern, E. A., & Lytle, F. W. (1971). New technique for investigating noncrystalline structures: Fourier analysis of the extended X-ray absorption fine structure. Physical Review Letters, 27(18), 1204-1207. DOI ↗Lee, P. A., & Pendry, J. B. (1975). Theory of extended x-ray absorption fine structure. Physical Review B, 11(8), 2795-2811. DOI ↗
AliasCI, configuration interaction method, CI calculationsEXAFS spectroscopy, X-ray absorption spectroscopyXANES spectroscopy, near-edge X-ray absorption
Terkait333
RingkasanConfiguration Interaction (CI) is a post-Hartree-Fock quantum chemistry method that improves upon mean-field molecular orbital theory by treating electron correlation through a linear combination of electronic configurations. Introduced by Roothaan in 1960, CI corrects for the fundamental limitation of single-determinant theory by allowing the wavefunction to be a superposition of excited-state Slater determinants, systematically accounting for electron-electron interactions.Extended X-ray Absorption Fine Structure (EXAFS) is a synchrotron-based X-ray spectroscopy technique that measures the local geometric and electronic structure around a specific atom in any material, crystal or amorphous. Discovered by Sayers, Stern, and Lytle in 1971, EXAFS reveals interatomic distances, coordination numbers, and disorder in the atomic environment by analyzing oscillations in the X-ray absorption spectrum above an absorption edge.X-ray Absorption Near Edge Structure (XANES) is a synchrotron X-ray spectroscopy technique that measures the electronic and geometric structure around a specific atom by analyzing the X-ray absorption spectrum within about 50 eV of an absorption edge. Developed by Lee and Pendry in 1975, XANES is complementary to EXAFS and reveals valence state, local symmetry, and unoccupied orbital structure through near-threshold features and resonances.
ScholarGateSet data
  1. v1
  2. 2 Sumber
  3. PUBLISHED
  1. v1
  2. 2 Sumber
  3. PUBLISHED
  1. v1
  2. 2 Sumber
  3. PUBLISHED

Ke halaman pencarian Unduh salindia

ScholarGateBandingkan metode: Configuration Interaction · EXAFS · XANES. Diakses 2026-06-19 dari https://scholargate.app/id/compare