ScholarGate
Asszisztens
Regression modelPhysical activity measurement / device calibration

Accelerometer Cut-Point Calibration

Accelerometer cut-point calibration solves the central translation problem of objective physical-activity measurement: a wearable accelerometer outputs dimensionless 'counts,' but researchers and health guidelines speak in intensities — sedentary, light, moderate, vigorous. Calibration establishes the count thresholds that map the device's output onto those intensity categories. Patty Freedson, Edward Melanson, and John Sirard's 1998 study of the CSA (later ActiGraph) accelerometer set the template, regressing measured energy expenditure in METs on accelerometer counts during treadmill walking and running and solving the regression for the counts corresponding to moderate (3 METs) and vigorous (6 METs) activity. Later work, exemplified by Evenson and colleagues' 2008 calibration for children, increasingly used receiver-operating-characteristic (ROC) analysis to find the cut-point that best discriminates intensity categories. The result in both cases is a small set of count thresholds that turn raw accelerometer data into minutes of activity at each intensity.

Megnyitás itt: MethodMindHamarosanAlkalmazás, összehasonlítás, útmutatás
Eszközök és források
Diák letöltése
Tanulás és felfedezés
VideóHamarosan

A teljes módszer elolvasása

Csak tagoknak

Jelentkezzen be ingyenes fiókkal a szakasz elolvasásához.

Bejelentkezés

Módszertérkép

A rokon módszerek környezete — válasszon ki egy csomópontot a felfedezéshez.

Források

  1. Freedson, P. S., Melanson, E., & Sirard, J. (1998). Calibration of the Computer Science and Applications, Inc. accelerometer. Medicine and Science in Sports and Exercise, 30(5), 777-781. DOI: 10.1097/00005768-199805000-00021
  2. Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008). Calibration of two objective measures of physical activity for children. Journal of Sports Sciences, 26(14), 1557-1565. DOI: 10.1080/02640410802334196

Hogyan hivatkozzon erre az oldalra

ScholarGate. (2026, June 23). Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC). ScholarGate. https://scholargate.app/hu/sport-leisure-studies/accelerometer-cut-point-calibration

Melyik módszer?

Állítsa e módszert a hozzá legközelebb álló rokonai mellé, és olvassa őket egymás mellett — a könyvtár az asztalra teszi a könyveket; a választás az Öné.

Összehasonlítás egymás mellett

Hivatkozik rá

ScholarGateAccelerometer Cut-Point Calibration (Accelerometer Cut-Point Calibration (Counts-to-Intensity Thresholds via Regression and ROC)). Letöltve 2026-06-24, forrás: https://scholargate.app/hu/sport-leisure-studies/accelerometer-cut-point-calibration · Adatkészlet: https://doi.org/10.5281/zenodo.20539026