ScholarGate
Assistant

Comparer des méthodes

Examinez les méthodes sélectionnées côte à côte ; les lignes qui diffèrent sont mises en évidence.

MALDI-TOF×Spectrométrie de masse par transformée de Fourier à cyclotron ionique (FT-ICR)×Résonance des Plasmons de Surface×
DomaineSpectroscopieSpectroscopieSpectroscopie
FamilleProcess / pipelineProcess / pipelineProcess / pipeline
Année d'origine198819741971
Auteur d'origineMichael KarasAlan MarshallErich Kretschmann
TypeIonization and mass analysis techniqueMass spectrometry techniqueOptical technique
Source fondatriceKaras, M., & Hillenkamp, F. (1988). Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Analytical Chemistry, 60(20), 2299-2301. DOI ↗Comisarow, M. B., & Marshall, A. G. (1974). Fourier transform ion cyclotron resonance spectroscopy. Chemical Physics Letters, 25(2), 282-283. DOI ↗Kretschmann, E. (1971). Determination of optical constants of metals by excitation of surface plasmons. Zeitschrift für Physik, 241(4), 313-324. link ↗
AliasMALDI mass spectrometry, MALDI-TOF-MS, laser desorption mass spectrometryFT-ICR-MS, Fourier Transform ICR, ICR mass spectrometrySPR, surface plasmon, SPR biosensing
Apparentées343
RésuméMatrix-Assisted Laser Desorption/Ionization (MALDI) combined with Time-of-Flight (TOF) mass analysis, or MALDI-TOF, is a soft ionization mass spectrometry technique that gently ionizes intact biomolecules and volatile organic compounds, then measures their mass-to-charge ratio by measuring flight time through a field-free drift region. Introduced independently by Karas, Hillenkamp, and Tanaka in 1988, MALDI-TOF revolutionized proteomics, microbiology, and organic analysis by enabling mass determination of proteins and polymers exceeding 100 kDa.Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry is an advanced analytical technique that combines magnetic confinement of ions with Fourier transform data processing to achieve exceptional mass accuracy and resolution. Developed by Comisarow and Marshall in 1974, FT-ICR-MS enables the determination of exact masses and elemental compositions of complex molecules, making it invaluable for environmental chemistry, metabolomics, petroleum characterization, and structural elucidation of unknowns.Surface Plasmon Resonance (SPR) is a real-time, label-free technique for detecting and monitoring biomolecular interactions at a sensor surface by measuring changes in the refractive index caused by ligand binding. Developed by Kretschmann in 1971 and applied to biosensing by Liedberg, Nylander, and Lundström in 1983, SPR is now a gold standard for measuring binding kinetics (association and dissociation rates) and equilibrium binding constants in protein interactions, antibody-antigen recognition, and drug discovery.
ScholarGateJeu de données
  1. v1
  2. 3 Sources
  3. PUBLISHED
  1. v1
  2. 3 Sources
  3. PUBLISHED
  1. v1
  2. 3 Sources
  3. PUBLISHED

Aller à la recherche Télécharger les diapositives

ScholarGateComparer des méthodes: MALDI-TOF · FT-ICR Mass Spectrometry · Surface Plasmon Resonance. Consulté le 2026-06-20 sur https://scholargate.app/fr/compare