ScholarGate
Assistant

Comparer des méthodes

Examinez les méthodes sélectionnées côte à côte ; les lignes qui diffèrent sont mises en évidence.

Analyse acoustique des bâtiments×Simulation de la lumière du jour×Évaluation Post-Occupation×Évaluation du confort thermique×
DomaineArchitectureArchitectureArchitectureArchitecture
FamilleProcess / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
Année d'origine1922200619881972
Auteur d'origineWallace Clement SabineChristoph Reinhart, John MardaljevicWolfgang PreiserPovl Ole Fanger
Typeroom acoustic prediction and assessment methodcomputational daylighting assessment methodempirical building evaluation methodpsychrometric comfort assessment method
Source fondatriceSabine, W. C. (1922). Collected Papers on Acoustics. Harvard University Press, Cambridge, MA. link ↗Reinhart, C. F., Mardaljevic, J., Rogers, Z. (2010). Dynamic Daylight Performance Metrics for Sustainable Building Design. Leukos, 3(1), 7-31. DOI ↗Preiser, W. F., Rabinowitz, H. Z., White, E. T. (1988). Post-Occupancy Evaluation. Van Nostrand Reinhold, New York. link ↗Fanger, P. O. (1972). Thermal Comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press, Copenhagen. link ↗
Aliassound analysis, room acoustic design, noise predictiondaylighting analysis, illuminance simulation, daylight availability assessmentPOE, building performance evaluation, occupant satisfaction assessmentthermal comfort evaluation, adaptive comfort model, PMV-PPD analysis
Apparentées3333
RésuméAcoustic Design Analysis is a method for evaluating the acoustical properties of buildings to predict sound levels, reverberation time, and speech intelligibility. Founded by Wallace Clement Sabine in the early 1900s, the field encompasses room acoustic design (controlling reverberation), sound transmission loss (preventing noise transfer between spaces), and environmental noise prediction.Daylight Simulation is a computational method for predicting the availability and distribution of daylight in interior spaces and assessing visual comfort under varying sky conditions. Developed by researchers like Christoph Reinhart and John Mardaljevic in the 2000s, it has become central to designing healthy, energy-efficient buildings that maximize natural light while controlling glare.Post-Occupancy Evaluation (POE) is a systematic method for assessing how well a completed building meets the needs and expectations of its occupants, comparing planned performance to actual performance. Formalized by Wolfgang Preiser in the 1980s, POE has become essential for learning what design strategies work, identifying problems for remediation, and improving future projects.Thermal Comfort Assessment is a method for evaluating indoor environmental conditions to predict whether occupants will feel thermally comfortable. Pioneered by Povl Ole Fanger in the 1970s, it combines measurements of air temperature, humidity, air speed, and thermal properties of clothing and activity to determine comfort zones and identify remedial actions.
ScholarGateJeu de données
  1. v1
  2. 3 Sources
  3. PUBLISHED
  1. v1
  2. 3 Sources
  3. PUBLISHED
  1. v1
  2. 3 Sources
  3. PUBLISHED
  1. v1
  2. 3 Sources
  3. PUBLISHED

Aller à la recherche Télécharger les diapositives

ScholarGateComparer des méthodes: Acoustic Design Analysis · Daylight Simulation · Post-Occupancy Evaluation · Thermal Comfort Assessment. Consulté le 2026-06-19 sur https://scholargate.app/fr/compare