ScholarGate
Trợ lý

So sánh phương pháp

Xem các phương pháp đã chọn cạnh nhau; những hàng khác biệt được làm nổi bật.

Độ trương nở và phân hủy×Giải phóng BMP×Phân tích Cơ động Lực học×
Lĩnh vựcVật liệu sinh họcVật liệu sinh họcVật liệu sinh học
HọProcess / pipelineProcess / pipelineProcess / pipeline
Năm ra đời196019651960
Người khởi xướngWichterle and LimMarshall UristFerry and Schwarzl
LoạiKinetic assayKinetic release assayRheological characterization
Công trình gốcWichterle, O., & Lim, D. (1960). Hydrophilic gels for biological use. Nature, 185(4706), 117-118. DOI ↗Urist, M. R. (1965). Bone: formation by autoinduction. Science, 150(3698), 893-899. DOI ↗Menard, K. P. (2008). Dynamic mechanical analysis: a practical introduction (2nd ed.). CRC Press. link ↗
Tên gọi kháchydrogel swelling, polymer degradation, mass loss assayBMP release kinetics, BMP elution profile, growth factor release assayDMA, rheological analysis, viscoelastic testing
Liên quan443
Tóm tắtThe swelling and degradation assay measures how biomaterial scaffolds absorb water (swelling) and lose mass over time due to degradation. Developed by Wichterle and Lim in 1960 for hydrogels, the assay is fundamental for characterizing hydrogels, synthetic polymers, and composite scaffolds intended for tissue engineering. The assay provides quantitative data on swelling kinetics (equilibrium water content, swelling ratio), degradation kinetics (mass loss rate, half-life), and mechanisms of degradation (chain scission, enzymatic breakdown).The bone morphogenetic protein (BMP) release assay measures the kinetics and amount of BMP elution from a biomaterial carrier over time. BMP-2, BMP-6, BMP-7, and BMP-9 are potent osteoinductive growth factors discovered by Marshall Urist in 1965 that trigger bone and cartilage formation. When loaded into scaffolds, hydrogels, or implants, BMPs must be released in a controlled manner to maximize biological effect while minimizing systemic exposure. The release assay quantifies how much BMP is present in the surrounding medium at defined timepoints, enabling optimization of carrier materials and release profiles for bone regeneration and fracture healing applications.Dynamic mechanical analysis (DMA) measures the viscoelastic properties of materials—their elastic stiffness and viscous damping—by applying a sinusoidal stress or strain and measuring the phase lag and amplitude of the material's response. Developed from rheology principles in the 1960s and formalized by Ferry, Schwarzl, and others, DMA provides quantitative measures of how polymeric biomaterials respond to time-dependent and frequency-dependent mechanical stimuli. Key outputs include the storage modulus (elastic component), loss modulus (viscous component), and loss tangent (tan δ), which together characterize the material's mechanical behavior across temperature and frequency ranges.
ScholarGateBộ dữ liệu
  1. v1
  2. 3 Nguồn tài liệu
  3. PUBLISHED
  1. v1
  2. 3 Nguồn tài liệu
  3. PUBLISHED
  1. v1
  2. 3 Nguồn tài liệu
  3. PUBLISHED

Đến trang tìm kiếm Tải xuống bản trình chiếu

ScholarGateSo sánh phương pháp: Swelling and Degradation · BMP Release · Dynamic Mechanical Analysis. Truy cập ngày 2026-06-19 từ https://scholargate.app/vi/compare