ScholarGate
Assistent

Jämför metoder

Granska de valda metoderna sida vid sida; rader som skiljer sig är markerade.

Post-Occupancy Evaluation×Dagsljussimulering×Bedömning av termisk komfort×
ÄmnesområdeArkitekturArkitekturArkitektur
FamiljProcess / pipelineProcess / pipelineProcess / pipeline
Ursprungsår198820061972
UpphovspersonWolfgang PreiserChristoph Reinhart, John MardaljevicPovl Ole Fanger
Typempirical building evaluation methodcomputational daylighting assessment methodpsychrometric comfort assessment method
UrsprungskällaPreiser, W. F., Rabinowitz, H. Z., White, E. T. (1988). Post-Occupancy Evaluation. Van Nostrand Reinhold, New York. link ↗Reinhart, C. F., Mardaljevic, J., Rogers, Z. (2010). Dynamic Daylight Performance Metrics for Sustainable Building Design. Leukos, 3(1), 7-31. DOI ↗Fanger, P. O. (1972). Thermal Comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press, Copenhagen. link ↗
AliasPOE, building performance evaluation, occupant satisfaction assessmentdaylighting analysis, illuminance simulation, daylight availability assessmentthermal comfort evaluation, adaptive comfort model, PMV-PPD analysis
Närliggande333
SammanfattningPost-Occupancy Evaluation (POE) is a systematic method for assessing how well a completed building meets the needs and expectations of its occupants, comparing planned performance to actual performance. Formalized by Wolfgang Preiser in the 1980s, POE has become essential for learning what design strategies work, identifying problems for remediation, and improving future projects.Daylight Simulation is a computational method for predicting the availability and distribution of daylight in interior spaces and assessing visual comfort under varying sky conditions. Developed by researchers like Christoph Reinhart and John Mardaljevic in the 2000s, it has become central to designing healthy, energy-efficient buildings that maximize natural light while controlling glare.Thermal Comfort Assessment is a method for evaluating indoor environmental conditions to predict whether occupants will feel thermally comfortable. Pioneered by Povl Ole Fanger in the 1970s, it combines measurements of air temperature, humidity, air speed, and thermal properties of clothing and activity to determine comfort zones and identify remedial actions.
ScholarGateDatamängd
  1. v1
  2. 3 Källor
  3. PUBLISHED
  1. v1
  2. 3 Källor
  3. PUBLISHED
  1. v1
  2. 3 Källor
  3. PUBLISHED

Gå till sökningen Ladda ner bildspel

ScholarGateJämför metoder: Post-Occupancy Evaluation · Daylight Simulation · Thermal Comfort Assessment. Hämtad 2026-06-20 från https://scholargate.app/sv/compare