Quantitative Susceptibility Mapping (QSM) is a post-processing technique that converts MRI phase data into quantitative susceptibility values, enabling direct visualization and measurement of tissue magnetic properties. Developed by Wang, Liu, and colleagues, QSM transforms phase shifts caused by differences in magnetic susceptibility between tissues into tissue-specific biomarkers. It has revolutionized the sensitivity of MRI to iron, calcium, and other paramagnetic and diamagnetic substances, making it valuable in neurodegenerative disease diagnosis and tissue characterization.

Sources recorded, not reviewed

Record di origine

Citazioni copiate testualmente dal record di origine del metodo. Non si inferisce alcuna verifica a livello di affermazione da esse.

Quantitative Susceptibility Mapping
Record tassonomico del metodo · process-pipeline / medical-imaging
  • Wang, Y., Liu, T. (2015). Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker. Magnetic Resonance in Medicine, 73(1), 82-101. · DOI 10.1002/mrm.25358
  • Liu, T., Spincemaille, P., de Rochefort, L., et al. (2009). Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from undersample phase data. Magnetic Resonance in Medicine, 66(3), 579-592. · URL
  • Haacke, E. M., Xu, Y., Cheng, Y. C., Reichenbach, J. R. (2004). Susceptibility weighted imaging (SWI). Magnetic Resonance in Medicine, 52(3), 612-618. · DOI 10.1002/mrm.20198
Apri metodo completo

Affermazioni curate

Affermazioni persistite nel registro delle evidenze, ciascuna con la propria valutazione.

Nessuna affermazione curata ancora

Questa vista non inventa una valutazione dell'affermazione quando il registro non ne ha.

Metodi correlati

Generato dal grafo dei metodi e mostrato come relazioni suggerite dalla macchina — nessuna affermazione di evidenza viene inferita.

Same method familyCT Iterative Reconstructionmachine-suggested · Relational suggestion, not evidence.Same method familyDTI Tractographymachine-suggested · Relational suggestion, not evidence.Same method familyFunctional Ultrasoundmachine-suggested · Relational suggestion, not evidence.Same method familyOCT Angiographymachine-suggested · Relational suggestion, not evidence.Same method familyPET Kinetic Modelingmachine-suggested · Relational suggestion, not evidence.

Stato evidenza

Sources recorded, not reviewed

Bibliographic sources are present. Claim-level evidence review has not been performed.

Fonti

3 citazioni registrate, copiate dal record di origine del metodo.

Azioni

Apri pagina del metodo
ScholarGate

Una biblioteca di riferimento incentrata sui contenuti, dedicata ai metodi di ricerca — che cos'è ciascun metodo, come funziona e da dove proviene.

Dati aperti (CC-BY)

Scopri

  • Biblioteca
  • Cerca metodi…
  • Sfoglia per campo
  • Campi
  • Viaggio
  • Confronta
  • Quale metodo?

Riferimento

  • Materie
  • Atlante
  • Glossario
  • Metodologia
  • Filosofia

Spazio di lavoro

  • La mia biblioteca
  • Banco
  • Chat

Azienda

  • Chi siamo
  • Prezzi
  • Contatti
  • Suggerisci un metodo

Le voci sono raccolte da fonti pubblicate a scopo di consultazione. La verifica dell'accuratezza e dell'idoneità di qualsiasi informazione per il proprio utilizzo resta responsabilità dell'utente.

© 2026 ScholarGate · Biblioteca di riferimento dei metodi di ricerca
  • Riservatezza
  • Cookie
  • Condizioni
  • Elimina account