ScholarGate
Avustaja

Vertaile menetelmiä

Tarkastele valitsemiasi menetelmiä rinnakkain; eroavat rivit korostetaan.

CFD-hemodynamiikka×Sydämen sykevälivaihtelu×Fotoplethysmografia×
TieteenalaBiomekaniikkaBiomekaniikkaBiomekaniikka
MenetelmäperheProcess / pipelineProcess / pipelineProcess / pipeline
Syntyvuosi200219961937
KehittäjäDavid SteinmanTask Force of European Society of CardiologyHertzman
TyyppiMulti-physics finite element simulationTime-series and frequency-domain analysis pipelineOptical signal acquisition and analysis pipeline
AlkuperäislähdeSteinman, D. A., Vinh, B., Ethier, C. R., Ojha, M., Cobbold, R. S., & Johnston, K. W. (2002). A numerical simulation of flow in a two-dimensional end-to-side anastomosis model. Journal of Biomechanical Engineering, 115(1), 112-118. link ↗Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. (1996). Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation, 93(5), 1043-1065. DOI ↗Allen, J. (2007). Photoplethysmography and its application in clinical physiology. Physiology & Behavior, 107(4), 540-548. link ↗
RinnakkaisnimetCardiovascular CFD, Blood flow simulation, Hemodynamic simulationHRV, RR interval analysis, Cardiac variabilityPPG, Pulse oximetry, Reflectance photometry
Liittyvät333
TiivistelmäComputational fluid dynamics (CFD) for hemodynamics solves the Navier-Stokes equations to simulate blood flow in realistic vascular geometries. Pioneered by researchers such as David Steinman, CFD hemodynamics reveals complex flow patterns, wall shear stress distributions, and hemodynamic factors implicated in atherosclerosis, aneurysm rupture, and device-induced thrombosis.Heart rate variability (HRV) analysis quantifies the variation in time intervals between consecutive heartbeats as a window into autonomic nervous system function and cardiovascular health. Formalized by the European Society of Cardiology Task Force in 1996, HRV metrics are now standard in cardiology, physiology, and sports science for assessing stress, recovery, and disease risk.Photoplethysmography (PPG) measures blood volume changes in tissue using light absorption, providing a non-invasive optical window into cardiovascular dynamics. Originally developed by Hertzman in 1937, PPG is now ubiquitous in pulse oximetry, smartwatches, and research applications for monitoring heart rate, blood oxygenation, and vascular function.
ScholarGateAineisto
  1. v1
  2. 2 Lähteet
  3. PUBLISHED
  1. v1
  2. 2 Lähteet
  3. PUBLISHED
  1. v1
  2. 2 Lähteet
  3. PUBLISHED

Siirry hakuun Lataa diat

ScholarGateVertaile menetelmiä: CFD Hemodynamics · Heart Rate Variability · Photoplethysmography. Haettu 2026-06-19 osoitteesta https://scholargate.app/fi/compare