ScholarGate
دستیار

مقایسهٔ روش‌ها

روش‌های انتخابی خود را کنار هم مرور کنید؛ ردیف‌های متفاوت برجسته شده‌اند.

Grip Strength Assessment×باتری کوتاه سنجش عملکرد فیزیکی×
حوزهSocial Gerontologyسالمندشناسی
خانوادهProcess / pipelineProcess / pipeline
سال پیدایش20111994
پدیدآورHelen C. Roberts, Avan Aihie Sayer and colleagues (standardization synthesis)Jack M. Guralnik
نوعPerformance measure of maximal isometric muscle strengthPerformance-based assessment
منبع بنیادینRoberts, H. C., Denison, H. J., Martin, H. J., Patel, H. P., Syddall, H., Cooper, C., & Sayer, A. A. (2011). A review of the measurement of grip strength in clinical and epidemiological studies: towards a standardised approach. Age and Ageing, 40(4), 423-429. DOI ↗Guralnik, J. M., Simonsick, E. M., Ferrucci, L., et al. (1994). A short physical performance battery assessing lower extremity function: association with self-reported disability and prediction of mortality and nursing home admission. J Gerontol, 49(2), M85-M94. DOI ↗
نام‌های دیگرHandgrip Strength, Hand Dynamometry, Maximal Isometric Grip Strength, HGSSPPB
مرتبط35
خلاصهGrip strength assessment measures the maximal isometric force a person can generate by squeezing a handheld dynamometer, providing a simple, objective marker of overall muscle strength. Although the test uses only the hand, grip strength correlates with strength elsewhere in the body and serves as a convenient proxy for total muscle function, which is why it is central to the assessment of sarcopenia and frailty. Roberts and colleagues' 2011 review in Age and Ageing synthesized how grip strength is measured across clinical and epidemiological studies and proposed a standardized approach, because variation in equipment, posture, and protocol had made results hard to compare. A standard protocol specifies a seated posture with the elbow flexed at ninety degrees, the use of a calibrated dynamometer such as the Jamar or Smedley, and recording the best of several maximal efforts. Low grip strength predicts a range of adverse outcomes — disability, longer hospital stays, slower recovery, multimorbidity, and mortality — independent of age and body size. Its speed, low cost, and strong prognostic value have made it a routine component of geriatric and population health assessment.The Short Physical Performance Battery (SPPB) is a performance-based assessment developed by Guralnik and colleagues in 1994 at the National Institute on Aging to measure lower extremity physical function and functional mobility in older adults. It is widely used in clinical practice and epidemiological research to predict disability, institutionalization, and mortality in community-dwelling seniors.
ScholarGateمجموعه‌داده
  1. v1
  2. 1 منابع
  3. PUBLISHED
  1. v1
  2. 3 منابع
  3. PUBLISHED

رفتن به جست‌وجو دریافت اسلایدها

ScholarGateمقایسهٔ روش‌ها: Grip Strength Assessment · SPPB. بازیابی‌شده در 2026-06-25 از https://scholargate.app/fa/compare