ScholarGate
Asistent

Porovnat metody

Prohlédněte si vybrané metody vedle sebe; řádky, které se liší, jsou zvýrazněny.

Detekce QRS podle Pan-Tompkinse×Variabilita srdeční frekvence×Fotopletysmografie×
OborBiomechanikaBiomechanikaBiomechanika
RodinaProcess / pipelineProcess / pipelineProcess / pipeline
Rok vzniku198519961937
TvůrceJiapu PanTask Force of European Society of CardiologyHertzman
TypDigital signal processing pipelineTime-series and frequency-domain analysis pipelineOptical signal acquisition and analysis pipeline
Původní zdrojPan, J., & Tompkins, W. J. (1985). A real-time QRS detection algorithm. IEEE Transactions on Biomedical Engineering, BME-32(3), 230-236. DOI ↗Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. (1996). Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation, 93(5), 1043-1065. DOI ↗Allen, J. (2007). Photoplethysmography and its application in clinical physiology. Physiology & Behavior, 107(4), 540-548. link ↗
Další názvyQRS detection, R-peak detection, Heartbeat detectionHRV, RR interval analysis, Cardiac variabilityPPG, Pulse oximetry, Reflectance photometry
Příbuzné333
ShrnutíThe Pan-Tompkins algorithm is a real-time QRS detection method for electrocardiograms (ECGs) that identifies the R-peaks (ventricular depolarization) and QRS complexes from continuous cardiac waveforms. Published by Jiapu Pan and Willis Tompkins in 1985, it remains a standard reference for ECG processing and is widely implemented in clinical monitoring systems.Heart rate variability (HRV) analysis quantifies the variation in time intervals between consecutive heartbeats as a window into autonomic nervous system function and cardiovascular health. Formalized by the European Society of Cardiology Task Force in 1996, HRV metrics are now standard in cardiology, physiology, and sports science for assessing stress, recovery, and disease risk.Photoplethysmography (PPG) measures blood volume changes in tissue using light absorption, providing a non-invasive optical window into cardiovascular dynamics. Originally developed by Hertzman in 1937, PPG is now ubiquitous in pulse oximetry, smartwatches, and research applications for monitoring heart rate, blood oxygenation, and vascular function.
ScholarGateDatová sada
  1. v1
  2. 2 Zdroje
  3. PUBLISHED
  1. v1
  2. 2 Zdroje
  3. PUBLISHED
  1. v1
  2. 2 Zdroje
  3. PUBLISHED

Přejít na hledání Stáhnout prezentaci

ScholarGatePorovnat metody: Pan-Tompkins QRS Detection · Heart Rate Variability · Photoplethysmography. Získáno 2026-06-20 z https://scholargate.app/cs/compare