ScholarGate
Асистент

Сравнение на методи

Прегледайте избраните методи един до друг; редовете с разлики са откроени.

Кръгов дихроизъм×MALDI-TOF×Рентгеново разсейване на малки ъгли (SAXS)×Резонанс на повърхностни плазмони×
ОбластСпектроскопияСпектроскопияСпектроскопияСпектроскопия
СемействоProcess / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
Година на възникване1969198819541971
СъздателJean-Claude FasmanMichael KarasOtto KratkyErich Kretschmann
ТипSpectroscopic methodIonization and mass analysis techniqueSynchrotron/X-ray techniqueOptical technique
Основополагащ източникGreenfield, N. J., & Fasman, G. D. (1969). Computed circular dichroism spectra for protein secondary structures. Biochemistry, 8(10), 4108-4116. DOI ↗Karas, M., & Hillenkamp, F. (1988). Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Analytical Chemistry, 60(20), 2299-2301. DOI ↗Glatter, O., & Kratky, O. (1982). Small Angle X-ray Scattering. Academic Press. link ↗Kretschmann, E. (1971). Determination of optical constants of metals by excitation of surface plasmons. Zeitschrift für Physik, 241(4), 313-324. link ↗
Други названияCD spectroscopy, circular dichroism, CD analysisMALDI mass spectrometry, MALDI-TOF-MS, laser desorption mass spectrometrySAXS, small-angle scatteringSPR, surface plasmon, SPR biosensing
Свързани3333
РезюмеCircular Dichroism (CD) spectroscopy measures the differential absorption of left- and right-circularly polarized light by optically active molecules, particularly proteins and nucleic acids. Introduced by Greenfield and Fasman in 1969, CD is a rapid, non-destructive technique for characterizing secondary structure (alpha-helix, beta-sheet), monitoring protein folding transitions, and assessing conformational changes in response to pH, temperature, or ligand binding.Matrix-Assisted Laser Desorption/Ionization (MALDI) combined with Time-of-Flight (TOF) mass analysis, or MALDI-TOF, is a soft ionization mass spectrometry technique that gently ionizes intact biomolecules and volatile organic compounds, then measures their mass-to-charge ratio by measuring flight time through a field-free drift region. Introduced independently by Karas, Hillenkamp, and Tanaka in 1988, MALDI-TOF revolutionized proteomics, microbiology, and organic analysis by enabling mass determination of proteins and polymers exceeding 100 kDa.Small-Angle X-ray Scattering (SAXS) is a solution-phase X-ray scattering technique that measures the overall shape and size of macromolecules and nanoparticles by analyzing scattering intensity at low angles (0.1-10 degrees). Developed by Kratky and colleagues in the 1950s, SAXS provides information about molecular radius, aggregation state, and overall shape without requiring crystallization or fixing, making it ideal for studying native protein conformations and dynamics.Surface Plasmon Resonance (SPR) is a real-time, label-free technique for detecting and monitoring biomolecular interactions at a sensor surface by measuring changes in the refractive index caused by ligand binding. Developed by Kretschmann in 1971 and applied to biosensing by Liedberg, Nylander, and Lundström in 1983, SPR is now a gold standard for measuring binding kinetics (association and dissociation rates) and equilibrium binding constants in protein interactions, antibody-antigen recognition, and drug discovery.
ScholarGateНабор от данни
  1. v1
  2. 2 Източници
  3. PUBLISHED
  1. v1
  2. 3 Източници
  3. PUBLISHED
  1. v1
  2. 2 Източници
  3. PUBLISHED
  1. v1
  2. 3 Източници
  3. PUBLISHED

Към търсенето Изтегляне на слайдове

ScholarGateСравнение на методи: Circular Dichroism · MALDI-TOF · SAXS · Surface Plasmon Resonance. Извлечено на 2026-06-19 от https://scholargate.app/bg/compare