ScholarGate
المساعد

قارن الطرق

راجع الطرق التي اخترتها جنبًا إلى جنب؛ الصفوف المختلفة مميَّزة.

MALDI-TOF×الدايكروازيّم الدائري×مطيافية الكتلة بالرنين الدوراني الأيوني بتحويل فورييه (FT-ICR)×رنين البلازمون السطحي×
المجالعلم الطيفعلم الطيفعلم الطيفعلم الطيف
العائلةProcess / pipelineProcess / pipelineProcess / pipelineProcess / pipeline
سنة النشأة1988196919741971
صاحب الطريقةMichael KarasJean-Claude FasmanAlan MarshallErich Kretschmann
النوعIonization and mass analysis techniqueSpectroscopic methodMass spectrometry techniqueOptical technique
المصدر التأسيسيKaras, M., & Hillenkamp, F. (1988). Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Analytical Chemistry, 60(20), 2299-2301. DOI ↗Greenfield, N. J., & Fasman, G. D. (1969). Computed circular dichroism spectra for protein secondary structures. Biochemistry, 8(10), 4108-4116. DOI ↗Comisarow, M. B., & Marshall, A. G. (1974). Fourier transform ion cyclotron resonance spectroscopy. Chemical Physics Letters, 25(2), 282-283. DOI ↗Kretschmann, E. (1971). Determination of optical constants of metals by excitation of surface plasmons. Zeitschrift für Physik, 241(4), 313-324. link ↗
الأسماء البديلةMALDI mass spectrometry, MALDI-TOF-MS, laser desorption mass spectrometryCD spectroscopy, circular dichroism, CD analysisFT-ICR-MS, Fourier Transform ICR, ICR mass spectrometrySPR, surface plasmon, SPR biosensing
ذات صلة3343
الملخصMatrix-Assisted Laser Desorption/Ionization (MALDI) combined with Time-of-Flight (TOF) mass analysis, or MALDI-TOF, is a soft ionization mass spectrometry technique that gently ionizes intact biomolecules and volatile organic compounds, then measures their mass-to-charge ratio by measuring flight time through a field-free drift region. Introduced independently by Karas, Hillenkamp, and Tanaka in 1988, MALDI-TOF revolutionized proteomics, microbiology, and organic analysis by enabling mass determination of proteins and polymers exceeding 100 kDa.Circular Dichroism (CD) spectroscopy measures the differential absorption of left- and right-circularly polarized light by optically active molecules, particularly proteins and nucleic acids. Introduced by Greenfield and Fasman in 1969, CD is a rapid, non-destructive technique for characterizing secondary structure (alpha-helix, beta-sheet), monitoring protein folding transitions, and assessing conformational changes in response to pH, temperature, or ligand binding.Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry is an advanced analytical technique that combines magnetic confinement of ions with Fourier transform data processing to achieve exceptional mass accuracy and resolution. Developed by Comisarow and Marshall in 1974, FT-ICR-MS enables the determination of exact masses and elemental compositions of complex molecules, making it invaluable for environmental chemistry, metabolomics, petroleum characterization, and structural elucidation of unknowns.Surface Plasmon Resonance (SPR) is a real-time, label-free technique for detecting and monitoring biomolecular interactions at a sensor surface by measuring changes in the refractive index caused by ligand binding. Developed by Kretschmann in 1971 and applied to biosensing by Liedberg, Nylander, and Lundström in 1983, SPR is now a gold standard for measuring binding kinetics (association and dissociation rates) and equilibrium binding constants in protein interactions, antibody-antigen recognition, and drug discovery.
ScholarGateمجموعة البيانات
  1. v1
  2. 3 المصادر
  3. PUBLISHED
  1. v1
  2. 2 المصادر
  3. PUBLISHED
  1. v1
  2. 3 المصادر
  3. PUBLISHED
  1. v1
  2. 3 المصادر
  3. PUBLISHED

انتقل إلى البحث تنزيل الشرائح

ScholarGateقارن الطرق: MALDI-TOF · Circular Dichroism · FT-ICR Mass Spectrometry · Surface Plasmon Resonance. استُرجع بتاريخ 2026-06-20 من https://scholargate.app/ar/compare