Hoppa till innehållScholarGate
BibliotekMitt bibliotekSkrivbordReview StudioAssistent
Logga in
Transwell Assay/Bevis
Metodbevispost

Transwell Assay

The Transwell assay (also called the Boyden chamber assay after its originator Stephen Boyden) is a quantitative method for measuring cell migration and invasion in response to chemical gradients or through matrix barriers. The assay uses a membrane insert with defined pore size suspended in a multi-well plate: cells are placed in the upper chamber, a chemoattractant is placed in the lower chamber, and cells that successfully migrate through the pores accumulate in the lower chamber, where they can be counted or visualized. Variants that coat the insert with matrix proteins (Matrigel, collagen) enable measurement of invasion capacity. The Transwell assay is a gold-standard method in cell biology for evaluating cell motility, tumor metastatic potential, and the effects of growth factors and inhibitory compounds.

Sources recorded, not reviewed

Källpost

Citat kopierade ordagrant från metodens källpost. Ingen verifiering på källnivå härleds från dem.

Transwell Migration and Invasion Assay
Taxonomisk metodpost · process-pipeline / biomaterials
  • Boyden, S. (1962). The chemotactic effect of mixtures of antibody and antigen on polymorphonuclear leucocytes. Journal of Experimental Medicine, 115(3), 453-466. · DOI 10.1084/jem.115.3.453
  • Albini, A., Iwama, Y., Odaka, C., & Bomstein, P. (1987). Exogenous ATIII inhibits basic fibroblast growth factor-induced angiogenesis in vitro. Proceedings of the National Academy of Sciences, 84(17), 6142-6146. · URL
  • Kramer, N., Walzl, A., Unger, C., et al. (2013). In vitro cell migration and invasion assays. Mutation Research/Reviews in Mutation Research, 752(2), 142-195. · DOI 10.1016/j.mrrev.2012.08.001
Öppna fullständig metod

Kuraterade påståenden

Påståenden lagrade i bevisloggen, var och en med sin egen bedömning.

Inga kuraterade påståenden ännu

Denna vy hittar inte på en påståendebedömning när loggen saknar en.

Relaterade metoder

Genererade från metodgrafen och visade som maskinföreslagna relationer – inga bevispåståenden härleds.

Same method familyCAM Assaymachine-suggested · Relational suggestion, not evidence.Same method familyLive/Dead Assaymachine-suggested · Relational suggestion, not evidence.Same method familyMTT/MTS Assaymachine-suggested · Relational suggestion, not evidence.Same method familyScratch Wound Assaymachine-suggested · Relational suggestion, not evidence.

Bevisstatus

Sources recorded, not reviewed

Bibliographic sources are present. Claim-level evidence review has not been performed.

Källor

3 registrerade citat, kopierade från metodens källpost.

Åtgärder

Öppna metodens sida
ScholarGate

Ett innehållsdrivet referensbibliotek för forskningsmetoder — vad varje metod är, hur den fungerar och varifrån den kommer.

Öppna data (CC-BY)

Upptäck

  • Bibliotek
  • Sök metoder…
  • Bläddra efter ämnesområde
  • Ämnesområden
  • Resa
  • Jämför
  • Vilken metod?

Referens

  • Ämnen
  • Atlas
  • Ordlista
  • Metodik
  • Filosofi

Arbetsyta

  • Mitt bibliotek
  • Skrivbord
  • Chatt

Företag

  • Om oss
  • Priser
  • Kontakt
  • Föreslå en metod

Posterna är sammanställda från publicerade källor för referensändamål. Att verifiera att informationen är korrekt och lämplig för din egen användning är ditt eget ansvar.

© 2026 ScholarGate · Ett referensbibliotek för forskningsmetoder
  • Integritet
  • Kakor
  • Villkor
  • Radera konto