Circular Dichroism
Also known as: CD spectroscopy, circular dichroism, CD analysis
Circular Dichroism (CD) spectroscopy measures the differential absorption of left- and right-circularly polarized light by optically active molecules, particularly proteins and nucleic acids. Introduced by Greenfield and Fasman in 1969, CD is a rapid, non-destructive technique for characterizing secondary structure (alpha-helix, beta-sheet), monitoring protein folding transitions, and assessing conformational changes in response to pH, temperature, or ligand binding.
Key highlights
- Rapid and non-destructive; spectra acquired in seconds to minutes
- Requires micrograms of protein; no isotopic labeling or crystallization needed
- Directly probes secondary structure without extensive interpretation
- Excellent for monitoring real-time kinetics of folding or binding transitions
Intuition
This section is available to Pro members. Upgrade to Pro
How it works
This section is available to Pro members. Upgrade to Pro
When to use it
Use CD spectroscopy to rapidly assess protein secondary structure content, monitor thermal denaturation or pH-induced folding changes, and detect conformational changes upon ligand binding. CD is ideal for sample-limited studies and high-throughput screening. Assumes the sample is soluble, non-aggregated, and optically clear in the measurement wavelength range. Works best for proteins > 5 kDa and nucleic acids > 20 base pairs.
Strengths & limitations
- Rapid and non-destructive; spectra acquired in seconds to minutes
- Requires micrograms of protein; no isotopic labeling or crystallization needed
- Directly probes secondary structure without extensive interpretation
- Excellent for monitoring real-time kinetics of folding or binding transitions
- Low sensitivity to tertiary structure details; cannot resolve individual residues or side-chain interactions
- Far-UV measurements (below 200 nm) require degassed samples and special cells; atmospheric absorption limits wavelength range
- Spectral overlap between different secondary structures limits quantitative accuracy; best estimates are ±5% error
- Aggregation, scattering, or light absorption by other components in the sample degrade signal
Common pitfalls
This section is available to Pro members. Upgrade to Pro
Applications
This section is available to Pro members. Upgrade to Pro
Frequently asked
What wavelengths are used in protein CD spectroscopy?
Far-UV CD (190-240 nm) detects peptide bond chromophore transitions and is most sensitive to secondary structure. Near-UV CD (250-350 nm) probes aromatic side chains (tryptophan, tyrosine) and provides information about tertiary structure and hydrophobic environment.
How accurate is secondary structure estimation from CD?
Typical accuracy is ± 5% for the major secondary structures (helix, sheet). Accuracy improves with good spectral quality, appropriate deconvolution algorithm, and high-quality reference datasets. Minor structures (turns, coils) are estimated less accurately.
Can CD detect protein-protein interactions?
Indirectly, yes. If a ligand or binding partner causes conformational change in the protein, CD will detect the shift in secondary structure. However, weak interactions that don't perturb secondary structure may not be detected; surface plasmon resonance or isothermal titration calorimetry are better for binding affinity determination.
Sources
- 1.Greenfield, N. J., & Fasman, G. D. (1969). Computed circular dichroism spectra for protein secondary structures. Biochemistry, 8(10), 4108-4116.
- 2.Yang, J. T., Wu, C. S., & Martinez, H. M. (1986). Calculation of protein conformation from circular dichroism. Methods in Enzymology, 130, 208-269.
You have read it. What now?
Cite this page